Ventilation
Natural Ventilation
FEDERAL LAW
183.630 - Standards for natural ventilation
(f) The minimum internal cross-sectional
area of the terminal fittings for flexible ventilation
ducts installed to meet the requirements of paragraph
(d) of this section must not be less than 80 percent
of the required internal cross-sectional area of the
flexible ventilation duct. |
Some of the flexible ventilation ducts that
are available for marine use may be fitted with terminal fittings
made to fit the duct. Some of these are designed to fit inside
the flexible duct. For these fittings the reduced cross-section
at the fitting is permitted to be not less than 80% of the
cross-section required for the flexible duct under consideration.
It is important to remember that this reduction in the cross-section
is only permitted inside a terminal fitting. No reduction
in cross-sectional area is permitted any place in the natural
ventilation system. Also, note that the 80% figure applies
to the required area of the duct. For example, if the required
area is 5 sq. in., but the installed duct has a cross-sectional
area of 8 sq. in., the 80% (minimum) figure applies to the
5 sq. in.
Figure 16 is a graph that is intended to aid
in determining compliance. The minimum terminal fitting cross-sectional
area must be at or above the 80% of required area line in
order to comply with this section of the regulation. The diameters
at the various areas are included on the graph to aid in evaluating
terminal fittings by simply measuring the inside diameters.
The following discussion and graph has assumed
that circular air ducts are used. If other shapes of flexible
ducts are used, the same principles apply, but their measurements
and area calculation must be appropriate for the shape under
consideration
FIGURE
16 - Terminal Fitting Area
TO COMPLY WITH THE LAW
- Is the cross-section of the terminal
fitting for a flexible duct at least 80% of the cross-sectional
area required for the duct?
|