CODE OF FEDERAL REGULATIONS – TITLE
46 – SHIPPING
PART 25—REQUIREMENTS
Subpart 25.30—Fire Extinguishing Equipment
Sec. 25.30-15—Fixed fire extinguishing
systems
(a) When a fixed fire extinguishing system is
installed, it shall be of an approved carbon dioxide type,
designed and installed in agreement with the applicable provisions
of subpart 76.15 of subchapter H (Passenger Vessels) of this
chapter.
Sec. 25.30-20—Fire extinguishing equipment
required
(a) Motorboats.
(1) All motorboats shall carry at least
the minimum number of hand portable fire extinguishers set
forth in Table 25.30-20(a)(1), except that motorboats less
than 26 feet in length, propelled by outboard motors and
not carrying passengers for hire, need not carry such portable
fire extinguishers if the construction of such motorboats
will not permit the entrapment of explosive or flammable
gases or vapors.
Table 25.30-20(a)(1)
|
Length, feet |
Minimum
number of B-1 hand portable fire extinguishers required1 |
|
No fixed fire extinguishing system
in machinery space |
Fixed fire extinguishing system in
machinery space |
| Under
16 |
1 |
|
| 16
and over, but under 26 |
1 |
|
| 26
and over, but under 40 |
2 |
|
| 40
and over, but not over 65 |
3 |
|
1 One B-11 hand
portable fire extinguisher may be substituted for two B-I
hand portable fire extinguishers.
(2) The intent of this regulation is illustrated
in Figure 25.30-20(a1) where fire extinguishers are required
if any one or more of the specified conditions exist, and
in Figure 25.30-20(a2) where specified conditions do not,
in themselves, require that fire extinguishers be carried.
Figure
25.30-20(a1)
Fire extinguishers are required if any one or
more of the following conditions exist (numbers identifying
conditions are the same as those placed in Figure 25.30-20
(a1)):
1. Closed compartment under thwarts and seats
wherein portable fuel tanks may be stored.
2. Double bottoms not sealed to the hull or
which are not completely filled with flotation material.
3. Close living spaces.
4. Closed stowage compartments in which combustible
or flammable materials are stowed.
5. Permanently installed fuel tanks.
Figure
25.30-20(a2)
The following conditions do not, in themselves,
require that fire extinguishers be carried (numbers identifying
conditions are the same as those placed in Figure 25.30-20(a2)):
1. Bait wells.
2. Glove compartments.
3. Buoyant flotation material.
4. Open slatted flooring.
5. Ice chests.
(b) Uninspected passenger vessels of at least
100 gross tons. All uninspected passenger vessels of at least
100 gross tons must carry onboard hand-portable and semi-portable
fire extinguishers per Table 76.50-10(a) in Sec. 76.50-10
of this chapter.
(c) Motor vessels.
(1) All motor vessels shall carry at least
the minimum number of hand portable fire extinguishers set
forth in Table 25.30-20(b) (1).
Table 25.30-20(b)(1)
|
Gross tonnage— |
Minimum
number of B-II hand portable fire extinguishers |
|
Over |
Not
Over |
|
.............. |
50 |
|
| 50 |
100 |
|
|
100 |
500 |
|
| 500 |
1,000 |
|
|
1,000 |
.............. |
|
(2) In addition to the hand portable fire
extinguishers required by paragraph (b)(1) of this section,
the following fire-extinguishing equipment shall be fitted
in the machinery space:
(i) One Type B-II hand portable fire extinguisher
shall be carried for each 1,000 B. H. P. of the main engines
or fraction thereof. However, not more than 6 such extinguishers
need be carried.
(ii) On motor vessels of over 300 gross
tons, either one Type B-III semiportable fire-extinguishing
system shall be fitted, or alternatively, a fixed fire-extinguishing
system shall be fitted in the machinery space.
(3) The frame or support of each Type B-III
fire extinguisher required by paragraph (b)(2)(ii) of this
section must be welded or otherwise permanently attached
to a bulkhead or deck.
(4) If an approved semiportable fire extinguisher
has wheels and is not required by this section, it must
be securely stowed when not in use to prevent it from rolling
out of control under heavy sea conditions.
(d) Barges carrying passengers.
(1) Every barge of 65 feet in length or less
while carrying passengers when towed or pushed by a motorboat,
motor vessel, or steam vessel shall be fitted with hand
portable fire extinguishers as required by Table 25.30-20(a)(1),
depending upon the length of the barge.
(2) Every barge of over 65 feet in length
while carrying passengers when towed or pushed by a motorboat,
motor vessel, or steam vessel shall be fitted with hand
portable fire extinguishers as required by Table 25.30-20(b)(1),
depending upon the gross tonnage of the barge.
[CGFR 65-50, 30 FR 16653, Dec. 30, 1965,
as amended by CGD 77-039, 44 FR 34132, June 14, 1979; CGD
97-057, 62 FR 51042, Sept. 30, 1997; USCG-1999-5040, 67 FR
34776, May 15, 2002]
Sec. 25.30-90—Vessels contracted for
prior to November 19, 1952
(a) Vessels contracted for prior to November
19, 1952, shall meet the applicable provisions of Secs. 25.30-5
through 25.30-20 insofar as the number and general type of
equipment is concerned. Existing items of equipment and installations
previously approved but not meeting the applicable requirements
for type approval may be continued in service so long as they
are in good condition. All new installations and replacements
shall meet the requirements of Secs. 25.30-5 through 25.30-20.
(b) [Reserved]
Previous |