CODE OF FEDERAL REGULATIONS – TITLE
33 – NAVIGATION AND NAVIGABLE WATERS
PART 183—BOATS AND ASSOCIATED EQUIPMENT
Subpart F—Flotation Requirements
for Inboard Boats, Inboard/Outdrive Boats, and Airboats
Sec. 183.114—Test of flotation materials
(a) Vapor test. The flotation material must
not reduce in buoyant force more than 5 percent after being
immersed in a fully saturated gasoline vapor atmosphere for
30 days at a minimum temperature of 38 deg. C.
(b) 24-hour gasoline test. The flotation material
must not reduce in buoyant force more than 5 percent after
being immersed for 24 hours at 23 plus or minus 2 deg. C in
reference fuel B, of ASTM D 471 (incorporated by reference,
see Sec. 183.5).
(c) 30-day gasoline test. The flotation material
must not reduce in buoyant force more than 5 percent after
being immersed for 30 days at 23 plus or minus 2 deg. C in
reference fuel B, of ASTM D 471 (incorporated by reference,
see Sec. 183.5).
(d) 24-hour oil test. The flotation material
must not reduce in buoyant force more than 5 percent after
being immersed for 24 hours at 23 plus or minus 2 deg. C in
reference oil No. 2, of ASTM D 471 (incorporated by reference,
see Sec. 183.5).
(e) 30-day oil test. The flotation material
must not reduce in buoyant force more than 5 percent after
being immersed for 30 days at 23 plus or minus 2 deg. C in
reference oil No. 2, of ASTM D 471 (incorporated by reference,
see Sec. 183.5).
(f) 24-hour bilge cleaner test. The flotation
material must not reduce in buoyant force more than 5 percent
after being immersed for 24 hours at 23 plus or minus 2 deg.
C in a 5-percent solution of trisodium phosphate in water.
(g) 30-day bilge cleaner test. The flotation
material must not reduce in buoyant force more than 5 percent
after being immersed for 30 days at 23 plus or minus 2 deg.
C in a 5-percent solution of trisodium phosphate in water.
(h) The buoyant force reduction in paragraphs
(a) through (g) of this section is measured in accordance
with ASTM D 2842 (incorporated by reference, see Sec. 183.5).
Table 183.114—Flotation Performance
Tests
|
Test 183.114 |
Area
183.110 |
|
(b) Engine-room bilge |
(c) Engine-room unless open to atmosphere |
(d)
Bilge |
| (a) Vapor test |
|
X |
|
| (b)
24 hour gasoline test |
|
|
X |
| (c) 30 day gasoline
test |
X |
|
|
| (d)
24 hour oil test |
|
|
X |
| (e) 30 day oil
test |
X |
|
|
| (f)
24 hour bilge cleaner test |
|
|
X |
| (g) 30 day bilge
cleaner test |
X |
|
|
[CGD 77-145, 43 FR 56859, Dec. 4, 1978;
44 FR 47934, Aug. 16, 1979, as amended by USCG-2000-7223,
65 FR 40059, June 29, 2000]
Previous |