Electrical Systems

Manufacturer Requirements

FEDERAL LAW

183.445 - Conductors: Protection

(a) Each conductor or group of conductors that passes through a bulkhead, structural member, junction box, or other rigid surface must be protected from abrasion.

A conductor or bundle of conductors must have abrasion protection, in addition to its own insulation, where it goes through a hole. This applies to holes in any rigid surface such as a bulkhead, junction box, electric panel, etc. Any means such as clamping, grommets, caulking, hose, bushings, taping, special devices or others may be used. Note the requirements for isolation bulkhead openings in section 183.410(c), if applicable.

TO COMPLY WITH THE LAW

  • Is each conductor or bundle of conductors protected from chafe where it passes through a bulkhead, structural member, junction box or other rigid surface?

FIGURE 21 - Abrasion Protection

Previous  | Next

 