Electrical
Systems
Manufacturer Requirements
FEDERAL LAW
183.425 - Conductors: General
(g) This section does not apply to communication
systems; electronic navigation equipment; electronic
circuits having current flow of less than one ampere;
conductors which are totally inside an equipment housing;
resistance conductors that control circuit amperage;
high voltage secondary conductors and terminations that
are in ignition systems; pigtails of less than seven
inches of exposed length; and cranking motor conductors. |
TO COMPLY WITH THE LAW
- No conductor smaller than No. 16 AWG
is used separately.
- Any No. 18 AWG conductor used is protected
in a suitable multiconductor sheath and does not extend
out of this sheath more than 30 inches.
NOTE PERMITTED EXCEPTIONS in 183.425 (g) |
FIGURE
19 - Permitted Conductor Size