TABLE 5E
Allowable Amperage of Conductors of 50 Volts or More When 25 or More Conductors are Bundled
| 25 or More Conductors Are Bundled |
|||||||||||||
| Temperature Rating Of Conductor Insulation |
|||||||||||||
| Conductor |
60¡C |
75¡C |
80¡C |
90¡C |
105¡C |
125¡C |
200¡C |
||||||
| Outside |
Inside |
Outside |
Inside |
Outside |
Inside |
Outside |
Inside |
Outside |
Inside |
Outside |
Inside |
Outside or |
|
| 16 |
6.0 |
3.5 |
6.0 |
4.5 |
8.0 |
6.2 |
10.0 |
8.2 |
10.0 |
8.5 |
12.0 |
10.7 |
14.0 |
| 14 |
8.0 |
4.6 |
8.0 |
6.0 |
10.0 |
7.8 |
12.0 |
9.8 |
14.0 |
11.9 |
16.0 |
14.2 |
18.0 |
| 12 |
10.0 |
5.8 |
10.0 |
7.5 |
14.0 |
10.9 |
16.0 |
13.1 |
18.0 |
15.3 |
20.0 |
17.8 |
22.0 |
| 10 |
16.0 |
9.3 |
16.0 |
12.0 |
20.0 |
15.6 |
22.0 |
18.0 |
24.0 |
20.4 |
28.0 |
24.9 |
28.0 |
| 8 |
22.0 |
12.8 |
26.0 |
19.5 |
28.0 |
21.8 |
28.0 |
23.0 |
32.0 |
27.2 |
36.0 |
32.0 |
40.0 |
| 6 |
32.0 |
18.6 |
38.0 |
28.5 |
40.0 |
31.2 |
40.0 |
32.8 |
48.0 |
40.8 |
50.0 |
44.5 |
54.0 |
| 4 |
42.0 |
24.4 |
50.0 |
37.5 |
52.0 |
40.6 |
54.0 |
44.3 |
64.0 |
54.4 |
68.0 |
60.5 |
72.0 |
| 3 |
48.0 |
27.8 |
58.0 |
43.5 |
60.0 |
46.8 |
62.0 |
50.8 |
72.0 |
61.2 |
78.0 |
69.4 |
84.0 |
| 2 |
56.0 |
32.5 |
68.0 |
51.0 |
70.0 |
54.6 |
72.0 |
59.0 |
84.0 |
71.4 |
90.0 |
80.1 |
96.0 |
| 1 |
66.0 |
38.3 |
78.0 |
58.5 |
84.0 |
65.5 |
84.0 |
68.9 |
98.0 |
83.3 |
106.0 |
94.3 |
112.0 |
| 0 |
78.0 |
45.2 |
92.0 |
69.0 |
98.0 |
76.4 |
98.0 |
80.4 |
114.0 |
96.9 |
122.0 |
108.6 |
130.0 |
| 00 |
90.0 |
52.2 |
106.0 |
79.5 |
114.0 |
88.9 |
114.0 |
93.5 |
132.0 |
112.2 |
142.0 |
126.4 |
148.0 |
| 000 |
104.0 |
60.3 |
124.0 |
93.0 |
132.0 |
103.0 |
132.0 |
108.2 |
154.0 |
130.9 |
164.0 |
146.0 |
172.0 |
| 0000 |
120.0 |
69.6 |
144.0 |
108.0 |
154.0 |
120.1 |
154.0 |
126.3 |
178.0 |
151.3 |
190.0 |
169.1 |
204.0 |